Isolated Power Panels
Bender’s standard healthcare panel provides isolated power service and protection to operating rooms and other critical care areas designated as “wet procedure” locations. Designed in strict compliance with requirements including NFPA 99, NFPA 70, CSA Z32, UL 1047, and UL 1022, Bender isolated power panels offer the most up-to-date technology for all isolated power distribution requirements. All of the various types of isolated power panels include a single-phase, low-leakage isolation transformer, with primary and secondary voltages configured at factory and rated to system requirements. They also include a primary circuit breaker, up to 16 branch circuit breakers (maximum allowed by UL), reference ground buses, and a LIM2010 line isolation monitor. The LIM2010 features self-calibration, a wide variety of alarms, including total hazard current (THC, configurable for 2 mA or 5 mA), voltage, overload, and more. All panels also offer transformer load and temperature monitoring as an integratable option.
Supported Accessories:
- MK2000 series remote indicators
- GPM series power/ground modules
- EDS series ground fault location equipment
- Bender remote communication system
- Connection to Bender remote stations, including the MK2430 and MK800
Isolated Power Panels with Receptacles and Ground Jacks
This specific unit includes a section for hospital grade power receptacles and/or ground jacks. In addition to the standard transformer load and temperature monitor integration option, this unit also has a customizable quantity of receptacles and/or ground jacks to choose from.
Supported Accessories:
- HGC series hospital grade ground cords
- MK2000 series remote indicators
- EDS series ground fault location equipment
- Bender remote communication system
- Connection to Bender remote stations, including the MK2430 and MK800
Isolated Power Panels with Circuit Control
This unit from Bender is unique in the sense that it is configured for x-ray and laser equipment at intervals up to 60 A (panel power rating permitting), up to 16 circuits. It also features a PLC-controlled receptacle control/lockout that is configured per system requirements. A limit switch to lock out power to other receptacles can also be integrated, as well as transformer load and temperature monitoring.
Supported Accessories:
- XRM series receptacle modules, configured with in-use lamps and MK2000 series remote indicator
- GPM series power/ground modules
- Bender remote communication system
- Connection to Bender remote stations, including the MK2430 and MK800
Dual Voltage Isolated Power Panels
This unit has dual voltage to fit the needs of the system. It also is the only unit to feature two reference ground buses. Included in the panel is one secondary main circuit breaker for the high voltage side. Like all isolated power panels from Bender, transformer load and temperature monitoring can be integrated.
Supported Accessories:
- HGC series hospital grade ground cords
- MK2000 series remote indicators
- EDS series ground fault location equipment
- Bender remote communication system
- Connection to Bender remote stations, including the MK2430 and MK800
Dual System Isolated Power Panels
Much like the dual voltage panels, the dual system isolated power panels can help fit your needs if you are dealing with multiple systems. With the standard transformer load and temperature monitoring, this panel also can integrate an onboard branch ground fault location system.
Supported Accessories:
- MK2000 series remote indicators
- GPM series power/ground modules
- EDS series ground fault location equipment
- Bender remote communication system
- Connection to Bender remote stations, including the MK2430 and MK800